PRODUCTS
UPA-130 with Integrated Absence of Voltage Test
The UPA-130 TEST has 12 LED indicators. The eight detector UPA-130 visually alerts to the presence of dangerous AC or DC (Store Energy) potentials occurring between any combination of the four monitored input lines (L1, L2, L3, GND). Two LED indicators are assigned to each input line and are designated “+” and “-”. For each input line carrying an AC potential (bi-polar) , both the “+” and “-” LEDs will be active. A DC or Stored Energy potential will illuminate the “+” LED for the positive line and the “-” LED for the negative line. The four additional LEDs indicate the absence of voltage TEST functionality: indication of voltage above the low end of the operational range, indication of voltage below the low end of the operational range
or indication of no voltage present, indication of low charge, and indication of charging. In order to initiate an absence of voltage test, the magnet (included) is waved in front of the unit near the “TEST” symbol. The UPA-130 TEST requires no batteries and will allow for 1-2 tests after a 15-minute charge and will be fully charged in 1 hour.
The UPA-130 Series is UL Listed under UL File Number E55826.
Find Your Part Number
Not sure? Call for help. Phone: 304-387-1200
Part Number
Description
The UPA-130 TEST has 12 LED indicators. The eight detector UPA-130 visually alerts to the presence of dangerous AC or DC (Store Energy) potentials occurring between any combination of the four monitored input lines (L1, L2, L3, GND). Two LED indicators are assigned to each input line and are designated “+” and “-”. For each input line carrying an AC potential (bi-polar) , both the “+” and “-” LEDs will be active. A DC or Stored Energy potential will illuminate the “+” LED for the positive line and the “-” LED for the negative line. The four additional LEDs indicate the absence of voltage TEST functionality: indication of voltage above the low end of the operational range, indication of voltage below the low end of the operational range or indication of no voltage present, indication of low charge, and indication of charging. In order to initiate an absence of voltage test, the magnet (included) is waved in front of the unit near the “TEST” symbol. The UPA-130 TEST requires no batteries and will allow for 1-2 tests after a 15-minute charge and will be fully charged in 1 hour. The UPA-130 Series is UL Listed under UL File Number E55826.
Find Your Part Number
Not sure? Call for help. Phone: 304-387-1200
Part Number | Description |
---|