Single/Dual Preset Counters
Single and Dual Preset Counters for Industrial Automation
ATC Diversified Electronics offers the 376B Series Digital Counter for industrial applications requiring accurate event counting, preset control, batch counting, totalizing, or high-speed pulse counting. The 376B is available in single preset and dual preset configurations, allowing the counter to be matched to the control sequence required by the machine or process.
The 376B combines a clear digital count display with programmable presets, multiple counting modes, adjustable input scaling, remote reset capability, and relay or transistor output options. Applications can include packaging equipment, conveyors, production machinery, material handling, batching, cut-to-length processes, machine-cycle counting, and other industrial systems that must count events and initiate an output when a programmed value is reached.
Single preset versions can count at frequencies up to 10 kHz in supported configurations, while an optional debounce function can reduce the accepted count rate to 100 Hz for slower electromechanical or contact-based inputs. Both single and dual preset versions also include an internal totalizing counter for accumulating counts across multiple operating cycles.
Why Choose the ATC 376B Digital Counter?
Single or Dual Preset Control: Select a single preset for applications requiring one programmed switching point or a dual preset configuration when two independently programmed count points are required.
Batch Counting: The dual preset version can be configured for batch counting, allowing the controller to manage individual counts within a larger production or process batch.
High-Speed Counting: The single preset 376B can count at frequencies up to 10 kHz in count-up mode, supporting compatible high-speed pulse sources such as sensors, encoders, and electronic control signals.
Internal Totalizer: An internal totalizing counter can accumulate counts across multiple cycles, providing a running total in addition to the active preset-counting function.
Multiple Count Modes: Available operating modes include bidirectional counting, quadrature counting, count with inhibit, and interval counting with a separate start input.
Programmable Scaling: The 376B provides an adjustable scale factor from 0.00001 to 9.99999, allowing incoming pulses to be converted into meaningful engineering or production units.
Flexible Input Compatibility: The counter supports sinking, sourcing, and TTL-compatible count inputs, making it adaptable to a variety of industrial sensors and control devices.
Relay or Transistor Outputs: Models are available with electromechanical relay outputs or NPN current-sinking transistor outputs to match different control-system requirements.
Plug-In 72mm Housing: The 376B uses a plug-in 72mm square panel housing designed for quick replacement and a fully gasketed, dust- and water-resistant installation.
Single Preset Counter Operation
A single preset counter compares the accumulated count to one programmed preset value. When that value is reached, the 376B can operate its selected output according to the configured counting and output behavior.
Preset values can be programmed from 1 to 999,999, making the counter suitable for applications ranging from short repetitive machine cycles to larger production quantities.
Dual Preset and Batch Counting
The dual preset 376B provides two programmable count setpoints and can also be configured for batch-counting applications. This allows one counter to manage more complex sequences where one count value initiates an intermediate action and another represents the completed cycle or batch.
Both preset configurations also include an internal totalizer, allowing cumulative production or machine-cycle information to be retained separately from the active preset count.
High-Speed Industrial Counting
The 376B supports high-speed electronic counting for applications using compatible proximity sensors, photoelectric sensors, encoders, or other pulse-producing devices. The single preset version can operate at up to 10 kHz in count-up mode.
A debounce circuit can also be enabled to limit one count input to 100 Hz. This is useful when the input signal comes from a mechanical contact or another device where contact bounce could otherwise create unwanted additional counts.
Bidirectional and Quadrature Counting
The 376B supports bidirectional counting as well as quadrature X1, X2, and X4 modes. These functions allow the counter to work with compatible directional pulse sources where both count magnitude and direction must be tracked.
Depending on the selected mode, the counter can count upward, downward, or respond to phase-related pulse inputs from compatible encoders and sensing devices.
Interval Counting and Count Inhibit
The 376B also supports interval counting with a separate start input. This allows counting to occur within a defined operating interval initiated by an external signal.
Count-with-inhibit operation provides another level of control by allowing the counting process to be temporarily prevented according to the configured control input.
Programmable Scaling and Decimal Position
A programmable scale factor from 0.00001 to 9.99999 allows the 376B to translate raw incoming pulses into a useful displayed quantity. Six selectable decimal-point positions provide additional flexibility when displaying scaled measurements or production values.
This can be useful when one sensor pulse does not directly correspond to one finished part, unit of length, machine cycle, or other quantity being monitored.
Relay and Transistor Output Options
The 376B can be ordered with either relay or NPN transistor outputs. Relay-output models provide contacts rated up to 7 amps at 30 VDC or 250 VAC for compatible loads, while the transistor version provides a current-sinking electronic output for compatible DC control circuits.
Output type should be selected according to the PLC, relay, contactor, machine-control input, or other equipment that will receive the counter's output signal.
Find the Right 376B Counter Configuration
Selecting the right single or dual preset industrial counter depends on the number of required presets, count direction, pulse frequency, batch-counting needs, input type, scale factor, output type, reset method, power supply, and whether totalized production counts must also be retained.
Explore the 376B Series above to compare single preset, dual preset, batch, relay-output, and transistor-output configurations for industrial counting, production monitoring, machine control, and automation applications.
Single and Dual Preset Counter FAQs
What is a preset counter?
A preset counter accumulates input pulses or events and compares the running count to a programmed target value. When the preset is reached, the counter can operate an output according to its configured control logic.
What is the ATC 376B Series Digital Counter?
The 376B is an industrial digital counter available in single preset or dual preset versions. It supports high-speed counting, batch counting, totalizing, programmable scaling, multiple count modes, and relay or transistor outputs.
What is the difference between a single preset and dual preset counter?
A single preset counter provides one programmed count setpoint. A dual preset counter provides two setpoints, allowing two separate count-based actions or stages within the same process.
Can the 376B operate as a batch counter?
Yes. The dual preset version of the 376B can be configured for batch counting, allowing individual counts to be grouped into larger production or process batches.
What preset range does the 376B support?
Preset values can be programmed from 1 to 999,999.
How fast can the 376B count?
The single preset 376B supports a maximum count frequency of 10 kHz in count-up mode under the specified configuration. Count speed can vary with operating mode and enabled functions.
What does the debounce function do?
The debounce function limits Count Input 1 to 100 Hz to help prevent unwanted multiple counts from mechanical contacts or other signals that may bounce when changing state.
Does the 376B include a totalizing counter?
Yes. Both the single preset and dual preset versions include an internal totalizing counter that can accumulate counts across multiple operating cycles.
What counting modes does the 376B support?
The 376B supports bidirectional counting, quadrature X1, X2, and X4 counting, count with inhibit, and interval counting with a separate start input.
Can the 376B count up and down?
Yes. The 376B supports count-up and count-down operation, along with bidirectional and quadrature counting modes for compatible applications.
What is quadrature counting?
Quadrature counting uses two phase-related pulse signals from a compatible encoder or similar device to determine both count movement and direction. The 376B supports X1, X2, and X4 quadrature modes.
What is interval counting?
Interval counting allows the 376B to count input pulses during a separately initiated operating interval. A dedicated start input is used to begin the interval-counting sequence.
What does count inhibit mean?
Count inhibit allows counting to be temporarily prevented by an external control condition without necessarily resetting the accumulated count.
Does the 376B support programmable scaling?
Yes. The 376B provides a programmable scale factor from 0.00001 to 9.99999 so incoming pulses can be converted into the desired displayed quantity.
How many decimal positions does the 376B provide?
The 376B provides six selectable decimal-point positions for scaled count displays.
What input types does the 376B support?
The 376B supports sinking, sourcing, and TTL-compatible input signals. The connected sensor or pulse source must be electrically compatible with the selected counter configuration.
What output options are available for the 376B?
The 376B is available with relay or NPN current-sinking transistor outputs. The appropriate output type depends on the control device or load receiving the counter signal.
What are the relay contact ratings on the 376B?
ATC specifies relay-output contacts rated at 7 amps at 30 VDC or 250 VAC, with a 1/4 horsepower rating for compatible applications.
Does the 376B retain settings if power is lost?
Yes. The 376B uses nonvolatile EEPROM memory. ATC specifies a minimum of 230,000 power-loss cycles and 10-year retention for the stored data.
What type of display does the 376B use?
The 376B uses an eight-digit, 14-segment blue vacuum fluorescent display for count and programming information.
How is the 376B mounted?
The 376B uses a plug-in 72mm square DIN panel housing. ATC also lists surface-mount and retrofit mounting accessories for compatible installations.
Where are single and dual preset counters used?
Applications can include packaging equipment, production machinery, conveyors, material handling, batching systems, cut-to-length equipment, process machinery, machine-cycle counting, and other automation systems that require a control action after a programmed number of events.
How do I choose the right 376B configuration?
Determine whether one or two presets are required, then consider batch counting, count direction, maximum pulse frequency, sensor input type, scaling requirements, relay or transistor output, reset method, power supply, and whether internal totalizing is required.