Multiple Channel Isolated Switch (ISO/ISL Series)
The ISO/ISL Series multiple channel devices are used to provide a
safe and reliable means of controlling loads from hazardous locations
without releasing sufficient energy under normal or abnormal conditions
to cause ignition of a flammable or combustible atmospheric
mixture while in its most easily ignited concentration. An isolated
output turns on when the corresponding control switch input from the
hazardous location is activated. When using normally closed control
switch inputs, a jumper should be installed between terminals 1 and
2. Normally open control switch inputs do not require the optional
jumper. When the
non-latching ISO Series control switch input is activated, its corresponding
output turns on. When the control switch input is deactivated,
its output turns off. When the latching ISL Series control
switch input 2, 3 or 4 is activated, its corresponding output turns on.
When control switch 2, 3 or 4 is deactivated, its corresponding output
remains latched on as long as control switch input 1 is activated;
otherwise it turns off immediately. Control switch input 1 also controls
output 1 just as in the non-latching ISO Series.
Find Your Part Number
Not sure? Call for help. Phone: 304-387-1200
Part Number
Description
The ISO/ISL Series multiple channel devices are used to provide a safe and reliable means of controlling loads from hazardous locations without releasing sufficient energy under normal or abnormal conditions to cause ignition of a flammable or combustible atmospheric mixture while in its most easily ignited concentration. An isolated output turns on when the corresponding control switch input from the hazardous location is activated. When using normally closed control switch inputs, a jumper should be installed between terminals 1 and 2. Normally open control switch inputs do not require the optional jumper. When the non-latching ISO Series control switch input is activated, its corresponding output turns on. When the control switch input is deactivated, its output turns off. When the latching ISL Series control switch input 2, 3 or 4 is activated, its corresponding output turns on. When control switch 2, 3 or 4 is deactivated, its corresponding output remains latched on as long as control switch input 1 is activated; otherwise it turns off immediately. Control switch input 1 also controls output 1 just as in the non-latching ISO Series.