CDD Series Universal DC Current Monitor
The CDD Series may be used as an OVER CURRENT Monitor OR an UNDER CURRENT Monitor. The CDD has adjustable Delay-on-Operate and adjustable Delay-on-Release time delays. When the current exceeds the preset current trip point for longer than the Delay-on-Operate time delay, the internal relay will energize (Pick-up). When the current drops below the preset current trip point for longer than the Delay-on-Release time delay, the internal relay will de-energize (Drop-out). When used as an Over Current Monitor the Delay-on-Operate time delay is used to override inrush periods. When used as an Under Current Monitor, the Delay-on-Release timer is used to override a temporary under current condition.
Features:
- Over or under current monitor (DC)
- Available ranges from 0.2 to 20 amps
- Lock shaft adjustments for Current trip point, Delay-on-operate time, and Delay-on-release time
- Automatic reset
Applications:
- Current demand level monitoring
- Conveyor or motor load jam detection
- Dull bit or blade detection
- Remote motor sensing
- Broken fan belt or chains detection
- Feed rate to keep two loads at their most efficient point
Find Your Part Number
Not sure? Call for help. Phone: 304-387-1200
Part Number
Description
The CDD Series may be used as an OVER CURRENT Monitor OR an UNDER CURRENT Monitor. The CDD has adjustable Delay-on-Operate and adjustable Delay-on-Release time delays. When the current exceeds the preset current trip point for longer than the Delay-on-Operate time delay, the internal relay will energize (Pick-up). When the current drops below the preset current trip point for longer than the Delay-on-Release time delay, the internal relay will de-energize (Drop-out). When used as an Over Current Monitor the Delay-on-Operate time delay is used to override inrush periods. When used as an Under Current Monitor, the Delay-on-Release timer is used to override a temporary under current condition.
Features:- Over or under current monitor (DC)
- Available ranges from 0.2 to 20 amps
- Lock shaft adjustments for Current trip point, Delay-on-operate time, and Delay-on-release time
- Automatic reset
- Current demand level monitoring
- Conveyor or motor load jam detection
- Dull bit or blade detection
- Remote motor sensing
- Broken fan belt or chains detection
- Feed rate to keep two loads at their most efficient point